ICH110L

Unparalleled homogeneity of temperature and humidity. For stability testing according to ICH – WHO – EMA – ASEAN – GMP – GLP – GCCP.

Temperature

Working temperature rangewithout humidity: 0 to +60 °C
Setting temperature range0 to +60 °C
Working temperature rangefrom +10°C up to +60°C with humidity and/or light
Setting accuracy temperature0.1 °C
Temperature sensor2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error

Humidity

Humidityhumidity supply with distilled water from external tank by self-priming pump
Humidificationhumidification by hot steam generator
Humidityactive humidifying and de-humidifying adjustable from 10-80 % rh with digital display of relative humidity – resolution of display 0.1 %, setting accuracy 0.5 %

Control of standard components

Lightillumination unit consisting of 3 fluorescent lights with cold white light (standard illuminant D65, 6.500K) and 2 UV-lamps in the spectral range of 320-400 nm
Lightdaylight and UV-light can be programmed individually via controller
Lightcold white light +/- 6 %, for UV-light +/- 10 %

Control technology

ControlCOCKPITTwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.
Language settingGerman, English, Spanish, French, Polish, Czech, Hungarian
TimerDigital backwards counter with target time setting, adjustable from 1 minute to 99 days
Function SetpointWAITthe process time does not start until the set temperature is reached
adjustable parameterstemperature (Celsius or Fahrenheit), fan speed, light, programme time, time zones, summertime/wintertime

Ventilation

Fanforced air circulation in working chamber adjustable from 10 to 100 % in 10 % steps

Communication

Documentationprogramme stored in case of power failure
ProgrammingAtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port

Safety

Temperature controlmechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature
Temperature controlover- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display
AutoSAFETYadditionally integrated over- and undertemperature protection “ASF”, automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature, compressor in case of undertemperature
Autodiagnostic systemintegral fault diagnostics for temperature and humidity control
Alarmvisual and acoustic

Heating concept

Air jacketair jacket heating system for gentle all-around heating
Heating conceptno drying-up of the load caused by the cooling device due to separation of thermal jacket from interior
Defrostinghighly efficient automatic defrosting system

Standard equipment

Works calibration certificatestandard values +10 °C and +37 °C, 60 % rh at +30 °C
Entry portEntry port (silicone), 40 mm clear diameter, moisture tight, can be closed by a silicone stopper, standard position at the back
Internals2 stainless steel grid(s), electropolished
Standard accessoriesWater tank including connection hose

Stainless steel interior

Dimensionsw(A) x h(B) x d(C): 560 x 480 x 400 mm (d less 33 mm for fan)
Volume108 l
Max. number of internals5
Max. loading of chamber150 kg
Max. loading per internal20 kg

Textured stainless steel casing

Dimensionsw(D) x h(E) x d(F): 745 x 1233 x 585 mm (d +56mm door handle)
Installationon lockable castors
Housingrear zinc-plated steel

Electrical data

Voltage Electrical load230 V, 50/60 Hz
approx. 1450 W
Voltage Electrical load115 V, 50/60 Hz
approx. 1450 W

Ambient conditions

Set UpThe distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.
Ambient temperature15 °C to 28 °C (up to 34 °C with limited temperature range)
Humidity rhmax. 70 %, non-condensing
Altitude of installationmax. 2,000 m above sea level
Overvoltage categoryII
Pollution degree2

Packing/shipping data

Transport informationThe appliances must be transported upright
Customs tariff number8419 8998
Country of originFederal Republic of Germany
WEEE-Reg.-No.DE 66812464
Dimensions approx incl. cartonw x h x d: 880 x 1410 x 810 mm
Net weightapprox. 109 kg
Gross weight cartonapprox. 137 kg

Standard units are safety-approved and bear the test marks

 

Temperature-humidity working range ICH

Not all climate chambers are the same. The humidity content of the chamber load, the ambient conditions and the respective temperature-humidity working range are decisive factors in the selection of the right appliance. In the adjacent diagram, you can see the possible temperature/humidity combinations for our climate chamber ICH.

Within the respective temperature-humidity range, condensation-free permanent operation is possible. To which extent condensation may occur in the threshold range depends on the humidity content of the chamber load and the ambient conditions.

Parameter

Humidity, Light, Temperature

Sector

Chemistry & Raw Material, Education & Research, Energy & Environment, Food & Beverage, Medical & Pharmacy, Metal & Electric

Size

Medium (108 – 256 liter volume)