Technical Specification


CalibrateThree freely selectable values: temperature, humidity, and CO2
InterfacesUSB-C; Ethernet LAN
TimerTimer – Process time starts immediately when the programme starts; Timer SetpointWAIT – Process time only starts after all setpoint values have been reached; Timer on Event – Process time starts at a defined point in time
Language settingsEnglish (default), German, French, Spanish, Portuguese, Chinese, Arabic, Hindi, Polish, Czech, Hungarian, Russian, Italian, Serbian
Appliance functionsDate and time (time zones, summer/winter time); Display brightness; DistanceView (1–4 freely selectable parameters, activation time adjustable); Network settings (IP, subnet, DHCP); Language and volume settings (buzzer/key tone); Power failure behaviour; Timer functions
Adjustable parametersTemperature; CO2; Humidity (requires option K7); O2 (requires option T6)
Control unit6.86″ IPS touch display (480 × 1280 pixels) with multi-touch function for graphical display of actual/setpoint values and parameter curves.

Control systemAnaerobic O2 control for targeted oxygen reduction via nitrogen inlet. Zirconium oxide sensor with integrated monitoring and error display. Filtered N₂ supply for safe process conditions.
Adjustment precision0,1 %
O2 – Setting range1 to 20 %

Temperature control systemLarge-area multi-zone multifunctional all-round heating with additional door, seal and rear wall heating
Setting temperature range+20 to +50 °C
Working-temperature range5 °C above ambient temperature up to +50 °C
Standard sterilisation programme: 60 minutes at 180°C (without removing the sensors)
Setting accuracy temperature0.1 °C
Temperature variation in chamberat + 37 °C +/- 0.3 K
Temperature fluctuations with timeat 37 °C +/- 0.1 K

Humidification systemPassive humidification by means of integrated water tank with condensate return via magnetically guided sealing lip. Humidity limitation by Peltier element. / Active closed-loop humidity control (option K7) with capacitive sensor for precise measurement and complete documentation. Humidification via self-priming micro-dosing pump with hot steam generation, dehumidification via powerful diaphragm pump.
Accuracy0,5% rh
Setting range40 to 98 and rh-Off

Control systemPrecise CO2 control with dual-beam NDIR technology, integrated monitoring and pressure-compensated measurement. Filtered CO2 supply for high process reliability.
Temporal fluctuation± 0,2 %
Setting range0 to 20 %

Power failureManual mode / Power failure less than 24 hours: Active process is terminated, parameters remain stored. Power failure longer than 24 hours: Operation continues with previously set parameters. Program mode (power failure >1 hour) / Failure less than 1 hour: Programme continues with remaining runtime. Failure longer than 1 hour: Programme is stopped; query for continuation required
Temperature monitoringDual Pt1000 sensor, DIN Class A, for mutual monitoring and automatic takeover in the event of a fault
Alarmvisual and acoustic

Standard optionDoor-open detection | V5
Factory calibration certificate III (Option T6)+37 °C, 5 %CO2, 90 %RH, 10 %O2
Factory calibration certificate II (Option K7)+37 °C, 5 %CO2, 90 RH
Factory calibration certificate I (Standard)+37 °C, 5 %CO2
Additional accessoriesCO2 connection set, hose with connection coupling and hose clamp; Water tank | B38737; Water tank including connection hose; Stored sterilisation programme: 60 minutes at +180 °C (without removing the sensors)
Doorfully insulated stainless steel door with 2-point locking (compression door lock)
Doorinner glass door with opening (8 mm Ø) to take gas sample
Internals1 perforated stainless steel shelf/shelves

Dimensionsw(A) x h(B) x d(C): 560 x 480 x 400 mm
Inner cover37,5 mm
Volume108 l
Max. number of internals5
Max. loading of chamber75 kg
Max. loading per internal15 kg

Dimensionsw(D) x h(E) x d(F): 708 x 683 x 589 mm
Installation4 adjustable appliance feet

Voltage Electrical load230 V, 50/60 Hz
approx. 1300 W
Voltage Electrical load115 V, 50/60 Hz
approx. 1300 W

Set UpThe distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.
Ambient temperature10 °C to 35 °C
Altitude of installationmax. 2,000 m above sea level
Overvoltage categoryII
Pollution degree2

Standard units are safety-approved and bear the test marks

Memmert’s digital ecosystem for networked laboratories and industrial applications.

myChamber’s digital solutions connect devices, data and users into an intelligent ecosystem – with remote monitoring, centralised device management and seamless workflow integration for complete transparency and control.

 

The myChamber ecosystem comprises four clearly structured solutions:

  • myChamber App: Remote monitoring of ongoing processes via smartphone
  • myChamber Control: Central device management and programming
  • myChamber LIMS: Automated, audit-compliant integration into LIMS systems
  • myChamber Link: Remote access to your devices

 

The best thing about it: myChamber is compatible with both the current generation of devices and Memmert’s next-gen device platform. No parallel software solutions, no isolated solutions – just a uniform, future-proof system landscape into which existing devices can also be seamlessly integrated.

myChamber Control

The myChamber ecosystem consists of four clearly structured digital solutions – most features free of charge.

Go to product

myChamber Monitoring App

Remote monitoring offers total control – anytime, anywhere.

Go to product

myChamber LIMS

Seamless data flow for fully connected labs.

Go to product

myChamber Link

The open interface for networked laboratory processes.

Go to product