Refrigerated and heated benchtop centrifuge
Sigma 2-16KHL
Easy operation, all-purpose
The Sigma 2‑16KHL refrigerated and heated model is the preferred choice for use with specimens whose viscosity needs to be reduced during centrifugation. It is also used in molecular biology to improve cell viability. Thanks to its compact design, it fits in every lab.
What makes the Sigma 2‑16KHL benchtop centrifuge so attractive
With a wide range of fixed-angle and swing-out rotors, this all-purpose centrifuge can hold PCR tubes, test tubes, round-bottom tubes, culture tubes and microtiter plates. This extensive range is rounded out by a haematocrit rotor.
The Sigma 2‑16KHL provides extraordinary capacity with 4 x 100 ml in a swing-out rotor or 6 x 50 ml in a fixed-angle rotor.
The Sigma 2‑16KHL has a high-performance, precisely adjustable refrigeration system with a temperature range of –10°C to +60°C. The Rapid Temp quick cooling function allows the centrifuge chamber and accessories to be pre-cooled to a defined temperature. This ensures optimal protection of specimens against heating.
Up to 50 different routine protocols can be stored in program memory and easily retrieved. Ten selectable acceleration and braking curves support the optimisation of separation processes.
Swing-out rotor
| max. volume | 400 ml |
| max. speed | 14,000 rpm |
| max. RCF | 16,215 x g |
Fixed-angle rotor
| max. volume | 450 ml |
| max. speed | 15,300 rpm |
| max. RCF | 21,913 x g |
Product options
- Inert gas port
User
- Food labs
- Universities & colleges
- Pharmaceutical labs
- Oil industry
Rotors

Swing-out rotor 11170 +
Bucket 13299
| 4 x 100 ml | |
| 5,000 rpm | |
| 3,969 x g |

Swing-out rotor 11124 +
Bucket 13124
| 24 x 2 ml | |
| 14,000 rpm | |
| 16,215 x g |

Swing-out rotor 11122 +
Bucket 13222
| 2 x 50 mm | |
| 3,000 rpm | |
| 1,218 x g |

Swing-out rotor 11123 +
Bucket 13223
| 2 x 50 mm | |
| 4,000 rpm | |
| 2,111 x g |

Fixed-angle rotor 12104
| 96 x 0,2 ml | |
| 14,000 rpm | |
| 21,475 x g |

Fixed-angle rotor 12148
| 24 x 2 ml | |
| 15,300 rpm | |
| 21,460 x g |

Fixed-angle rotor 12132
| 30 x 2 ml | |
| 14,000 rpm | |
| 21,913 x g |

Fixed-angle rotor 12180
| 12 x 5 ml | |
| 15,000 rpm | |
| 20,124 x g |

Fixed-angle rotor 12141
| 10 x 10 ml | |
| 15,300 rpm | |
| 19,890 x g |

Fixed-angle rotor 12071
| 6 x 50 ml + 12 x 15 ml | |
| 4,000 rpm | |
| 2,254 x g |

Fixed-angle rotor 12072
| 20 x 15 ml | |
| 4,000 rpm | |
| 2,486 x g |

Fixed-angle rotor 12073
| 30 x 15 ml | |
| 4,000 rpm | |
| 2,486 x g |

Fixed-angle rotor 12139
| 6 x 30 ml | |
| 15,300 rpm | |
| 20,414 x g |

Fixed-angle rotor 12181
| 6 x 50 ml | |
| 12,000 rpm | |
| 15,294 x g |

Fixed-angle rotor 12138
| 4 x 85 ml | |
| 9,400 rpm | |
| 9,484 x g |

Fixed-angle rotor 11409
| 24 x capillary tubes | |
| 12,000 rpm | |
| 14,489 x g |
Technical specifications
| Max. capacity [ml] | |
| swing-out rotor | 4 x 100 |
| fixed-angle rotor | 4 x 85 |
| Max. RCF | 21.913 |
| Max. speed [rpm] | 15.300 |
| Min. speed [rpm] | 100 |
| Noise level at maximum speed (approximate) [dB(A)] | |
| fixed-angle rotor 12141 | ≤ 53 |
| swing-out rotor 11170 with bucket 13299 + Cover | ≤ 52 |
| Max. acceleration time [s] | |
| fixed-angle rotor 12141 | 31 |
| swing-out rotor 11170 with bucket 13299 + Cover | 17 |
| Max. braking time [s] | |
| fixed-angle rotor 12141 | 37 |
| swing-out rotor 11170 with bucket 13299 + Cover | 15 |
| Temperature setting range [°C] | -10 – +60 |
| Power consumption [W] | 720 |
| Height x Width x Depth [mm] | 310 x 550 x 570 |
| Height with open lid [mm] | 705 |
| Weight without rotor [kg] | 60 |
| Refrigerant | R513a |
| Charge [kg] / Pressure [bar] | 0,255 / 23 |
| CO2 equivalent [t] | 0,161 |
| Contains fluorinated greenhouse gases in a hermetically sealed refrigeration system. (EU) 2024/2729; 2028-DEC-31. | |