Menu

Digital Dissolution Offline System

The Digital Offline System for the DT 950 and 9510 series is the next step in harnessing the power of digital dissolution testing. It extends the advanced technology of the DT 950 and 9510 series with the first step in dissolution automation: fully automated sampling and storage in vials for separate analysis.

The Digital Offline System for the DT 950 and 9510 series is the next step in harnessing the power of digital dissolution testing. It extends the advanced technology of the DT 950 and 9510 series with the first step in dissolution automation: fully automated sampling and storage in vials for separate analysis.

With the updated TestAssist, the user can easily configure and start dissolution tests with automatic sampling on our 7-inch touch display. The design principles introduced with the DT 950 have been applied to offline testing, making it faster, easier and more accurate than ever before. The user is guided through the dissolution test with automatic sampling in a few simple steps. This enables 100% USP / EP / JP compliant dissolution testing without distraction or error and ensures consistently compliant parameters.

But it doesn’t stop there – with user management, conformant handling of the complete Digital Offline system is just the touch of a button away. Users can be easily configured with individual rights, making it easy to restrict functions to authorized users only – such as administrators, operators and service technicians.

The Digital Offline System is our most advanced stand-alone resolution system and provides an easy-to-use entry point into resolution automation.

 

TestAssist for Digital Dissolution Offline Testing

The intelligent TestAssist has been updated for digital offline testing:

  • Easy sample timing configuration
  • Advanced offline system settings
  • Updated test interface for more information and transparency in the test procedure

 

 

 

User Management

The updated user management enables flexible access control for the digital dissolution system:

  • Easy-to-use user rights management
  • Password complexity guidelines for safe access control

 

 

 

 

 

Stand-Alone Control of Connected Hardware

The digital embedded PC technology in the digital dissolution tester DT 950 and DT 9510 take full control of the connected system hardware: The pump, either PVP or IPC, the automated sampling station ASS-9/-18 and the sample collector. An external computer is not required, saving space, energy and maintenance, and thanks to the digital technology, without loosing comfortable features and USP/EP/JP compliance. Of course, the offline system includes all the other software features of the DT 950 platform, including method memory, sampling station with temperature sensors in each vessel, USB update and FTP data export.

Documents


Digital Offline Systems

Dissolution Guide

Tablet test equipment overview

 

DT 950

Technical Data

 

Weight 42 kg
Dimensions (H x W x D) 850 x 650 x 650 mm
Voltage 115/230 V; 50/60 Hz
Speed 20-250 U/min
Vessel volume 400 ml / 1000 ml / 2000 ml
Interfaces 1x RS-232, 2x USB, 2x Ethernet/RJ45
Test stations (DT 956) 6 in 2 rows
Test stations (DT 957) 7 in 2 rows
Test stations (DT 958) 8 in 2 rows
USP methods USP 1 / USP 2 / USP 5 / USP 6
Fuses 2 A
Protection class I/EN 61140
Protection type IP 21/IEC 529
Operation Touchscreen 7″, 800×480 Pixel
Sampling positions High-head / Low-head / Cleaning mode
Ambient temperature during operation +10 °C to +30 °C (ambient temperature min. -5 °C below set temperature)
Storage & Transport temp. +5 °C to +40 °C
Relative humidity 25-80 % non condensing

DT 9510

Technical Data

Weight 110 kg
Dimensions (H x W x D) 850 x 1062 x 650 mm
Voltage 115/230 V; 50/60 Hz
Speed 20-250 U/min
Vessel volume 400 ml / 1000 ml / 2000 ml
Interfaces 1x RS-232, 2x USB, 2x Ethernet/RJ45
Test stations (DT 9512) 12 in 2 rows
Test stations (DT 9513) 13 in 2 rows
Test stations (DT 9514) 14 in 2 rows
USP methods USP 1 / USP 2 / USP 5 / USP 6
Fuses 2 A
Protection class I/EN 61140
Protection type IP 21/IEC 529
Operation Touchscreen 7″, 800×480 Pixel
Sampling positions High-head / Low-head / Cleaning mode
Ambient temperature during operation +10 °C to +30 °C (ambient temperature min. -5 °C below set temperature)
Storage & Transport temp. +5 °C to +40 °C
Relative humidity 25-80 % non condensing

Sample Collector FRL 6/7/854

Technical Data

Weight 25 kg
Dimensions (H x W x D) 585 x 700 x 515 mm
Channels 6,7 or 8
Max. capacity (not for 25 ml test tubes) 26 sample intervals
Valve Integrated 3 way valves
FRL racks 26 x 8 / 1.5 ml HPLC vials, 26 x 8 / 4.0 ml HPLC vials, 26 x 8 / 10 ml test tubes, 18 x 8 / 25 ml test tubes
Voltage +- 10% 115 – 250 VAC; 50 / 60 Hz

PVP Pump x20

Technical Data

Weight 28 kg (for PVP 1220/1420)
Dimensions (H x W x D) 420 x 275 x 575 mm (for PVP 1220/1420)
Voltage 115 V or 230 V, 50/60 Hz
Pump type PVP 1220/1420 (for DT 9510)
Channels 12 or 14 (for PVP 1220/1420)
Valves /
Accuracy +/- 0.5 ml
System compatibility DT Online System, DT Offline System, DT On-/Offline System
Benefits Filtration down to 0.22 μm with a flat membrane filtration. Particularly suitable for fully automatic dissolution systems.

IPC Pump 8/16

Technical Data

Dimensions (H x W x D) 125 x 145 x 220 mm
Interfaces RS 232
Channels 8 or 16
Accuracy 25 ml +/− 5%
Media replacement Standard
Double filtration (optional) Only when first filtration with poroplast filters. No media replacement possible when double filtration.
Required type of sample collector FRL 654 / 754 / 854
System compatibility DT Offline / DT Online / DT On-/Offline
Advantages Basic pump possible with DT 950/9510, needs regular replacement of tubing